|  DATALOGGER I-log
| I - Log intelligent loggers provide you
with the technological facilities to introduce total quality control for
temperature and humidity sensitive products and services while supporting
your compliance with the stringent monitoring requirements of today's
markets. With the extended functionality of its display the i - Log supplies
you instantly with all the information required
Due to its combination of great resolution and high accuracy, the i -
Log can detect and record the smallest fluctuations in temperature for
the tight monitoring of critical conditions. You benefit from the confidence
and security of having precise relevant information at your fingertips.
|
 |
- Multi functional display
- FAST download to PC (35 seconds to download 16,000
readings)
- 0.1°Resolution
- High Accuracy
- Intuitive Software for ease of use
COMMON TECHNICAL FEATURES
| TEMPERATURE RANGE |
-40 +70°C |
| RESOLUTION |
0.1°C |
| ACCURACY |
+/- 0.3°C |
| IP RATING |
IP67 Internal/IP51 External |
| UMIDITY RANGE |
0 +100% UR |
| RESOLUTION |
0.1%UR |
| ACCURACY |
+/-3% @ 25°C |
| DATA RECOVERY |
Via PC Interface + Software |
| GREEN LED |
Active |
| RED LED |
Alarm |
| RESPONSE TIME |
Temperature sensor
Humidity sensor 10 sec ambient
(T90 in moving air) |
| TIME – DATA |
Real time clock
accuracy better than 40 seconds/month |
| SAMPLING FREQUENCY |
1 second to 255 minutes |
| SOFTWARE |
Console Software for Windows™ |
| RECORDER START UP |
Programmed time – date
Or magnet swipe |
| POWER SOURCE |
1 Lithium battery |
| BATTERY LIFE |
Depending on frequency of PC comunication |
| CASE MATERIAL |
Polycarbonate |
TECHNICAL FEATURES
EI-1ND-32L
i-LOG for TEMPERATURE 1 Internal sensor |
| TEMPERATURE RANGE |
-40 +70°C |
| RESOLUTION |
0.1°C (0.2°F) |
| ACCURACY |
±0.3°C |
| LED |
Green LED = Active/Red LED = Alarm |
| IP RATING |
IP67 Internal IP51 External |
| MEMORIA |
32.000 letture |
| TEMPERATURE RESPONSE |
Internal sensor T90 1 min |
| SAMPLING FREQUENCY |
1 sec – 255 min |
TYPICAL BATTERY LIFE
|
Dependent on frequency of PC communication |
| SIZE |
ø 76 mm, Ht. 36 mm |
| WEIGHT |
70 gr |
|
EI-1ED-32L
i-LOG for TERMPERATURE 1 Internal + 1 External sensors |
| TEMPERATURE RANGE |
-40 +70°C (-40 +158°F) |
| RESOLUTION |
0.1°C (0.2°F) |
| ACCURACY |
±0.3°C |
| LED |
Green LED = Active/Red LED = Alarm |
| IP RATING |
IP67 |
| MEMORY |
32.000 readings |
| TEMPERATURE RESPONSE |
Internal sensor T90 1 min
External sensor T90 4 min
(in moving air) |
| SAMPLING FREQUENCY |
1 sec – 255 min |
TYPICAL BATTERY LIFE
|
1 Litio / 1-2 anni approx. |
| SIZE |
ø 76 mm, Ht. 36 mm |
| WEIGHT |
70 gr |
|
EI-1ED-32L
i-LOG for TERMPERATURE 1 Internal + 2 External sensors |
| TEMPERATURE RANGE |
-40 +70°C (-40 +158°F) |
| RESOLUTION |
0.1°C (0.2°F) |
| ACCURACY |
±0.3°C |
| LED |
Green LED = Active/Red LED = Alarm |
| IP RATING |
IP67 |
| MEMORY |
32.000 readings |
| TEMPERATURE RESPONSE |
Internal sensor T90 1 min
External sensors T90 4 min
(in moving air) |
| SAMPLING FREQUENCY |
1 sec – 255 min |
TYPICAL BATTERY LIFE
|
1 Litio / 1-2 anni approx. |
| SIZE |
ø 76 mm, Ht. 36 mm |
| WEIGHT |
70 gr |
|
EI-HSD32L
i-LOG per TERMPERATURA + HUMIDITY |
| TEMPERATURE RANGE |
-40 +70°C (-40 +158°F) / 0 –
100% UR |
| RESOLUTION |
0.1°C (0.2°F) / 0.1% UR |
| ACCURACY |
±0.3°C / +-/3% UR |
| LED |
Green LED = Active /Red LED =Alarm |
| IP RATING |
IP51 |
| MEMORIA |
32.000 readings: 16.000 - °C / 16.000 - UR |
| TEMPO DI RISPOSTA |
Internal sensor T90 1 min
External sensors T90 4 min
(in moving air) |
| SAMPLING FREQUENCY |
1 sec – 255 min |
| TYPICAL BATTERY LIFE |
Dependent on frequency of PC communication |
| SIZE |
ø 76 mm, Ht. 36 mm |
| WEIGHT |
70 gr |
|
| MLLINK |
PC Interface for MonoLog 2 and i-Log Series |
| MA-SWP-WIN |
Software for MonoLog 2 and i-Log Series |
| MLKEY |
Start magnet key ring |
 |
 |
|