Specifiche del datalogger multiparamentro per l'energia YL-M42

| YL-M42 Pulse Log | ||||||||
| Sensor type | 2 x input channel | |||||||
| Internal temperature range / resolution | NA | |||||||
| External temperature range / resolution | NA | |||||||
| Temperature operating range with CR2477N battery **** |
-30 to +70°C by default * | |||||||
| Temperature operating range with CR2450HT battery |
-40...+90°C | |||||||
| Humidity sensor (internal & external) range/resolution | NA | |||||||
| Condensation sensor | bedewed / dry | |||||||
| Cable | NA | |||||||
| Accuracy | NA | |||||||
| Meauring pulses (potential-free) / range/ resolution | 0 to 65 000 pulses, interval of 0 to 100 pulses / sec. 1Hz / 1 pulse | |||||||
| Voltage pulses / range/ resolution | 0 to 65 000 pulses, interval of 0 to 100 pulses / sec. 1Hz / 1 pulse | |||||||
| Signal input | Potential-free signals or low level pulses < 0,5 VDC and high level between 2 and 3 VDC can be processed. ** | |||||||
| Mesuring range Light/relative humidity/temperature | NA | |||||||
| Dimensions d x h (mm) | 50/30 | |||||||
| Memory capacity/optional | 100,000 readings/ 4 million readings | |||||||
| Interval | 1sec to 24h | |||||||
| Enclosure | Robust, shock-proof POM, protection class IP65 | |||||||
| Standard lithium battery life | NA | |||||||
| Included in delivery | Data logger, 1 battery, YoyoView Software, USB cable, connection cable YY-CS(max.5V), manual, declaration of conformity | |||||||
| Optional | YY-CP connection cable (2 m for pulses with voltages from 5 to 24V YoyoView Plus Software, calibration certificate | |||||||
* Using the logger within the extended operating range requires
the use of the CR2450HT battery.
** Higher levels up to 24 V require the YY-CP cable.
*** Higher levels require up to 24 V DKC-P cable.
**** PVC cable type V can be used from -20 to +80°C, Teflon cable
type G can be used from -70 to +250°C. The humidity probe YS-RHT120
may be used only between -40 to +120°C.
| Strain gauges measurements as bridge circuits (for full bridges 60...700Ohm) | |||||
| Range mV | ± 5 | ± 10 | ± 20 | ± 50 | ± 100 |
| Resolution µV * | 0.15 | 0.3 | 0.6 | 0.8 | 1.5 |
| Input impendance Mohm | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
* Strain gauge measurements allow a sample rate of up to 32 Hz in fast mode. The maximum resolution is ten times of the above value.
| Strain gauges measurements as bridge circuits (for full bridges 60...700Ohm) | ||||||
| Range mV | ± 5 | ± 10 | ± 20 | ± 50 | ± 100 | ± 1000 |
| Resolution µV * | 0.15 | 0.3 | 0.6 | 0.8 | 1.5 | 15 |
| Input impendance Mohm | 1 | 1 | 1 | 1 | 1 | 1 |
* High impedance mode allows for a maximum sample rate of 1 Hz.
| Input ranges | ||||||||
| Range mV | 0 to 10 | 0 to 20 | 0 to 50 | 0 to 100 | 0 to 1V | 0 to 2.5V | 0 to 5V | 0 to 10V |
| Resolution µV * | 0.58 | 0.58 | 0.76 | 1.54 | 15.4 | 38.9 | 76.9 | 154 |
| Input impendance Mohm | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 0.1 | 0.1 |
* input ranges can be measured at 32 Hz. At 32 Hz the maximum
resolution is ten times of the above value.
| Input ranges | |||||
| Range mV | 0 to 1V | 0 to 2.5V | 0 to 5V | 0 to 10V | 0 to 24mA |
| Resolution µV * | 15.4 | 38.9 | 76.9 | 154 | 0.36µA |
| Input impendance Mohm | 0.1 | 0.1 | 0.1 | 0.1 | 10 Ohmshunt |
* input ranges can be measured at 32 Hz. At 32 Hz the maximum
resolution is ten times of the above value.
Note: A YY - CU cable with integrated potential divider is required
in order to connect voltage signals. Current signals require the
YY-CI cable.
| Voltage and current | ||||||||
| Range mV | 0 to 10 | 0 to 20 | 0 to 50 | 0 to 100 | 0 to 1V | 0 to 2.5V | 0 to 5V | 0 to 10V |
| Resolution µV * | 0.58 | 0.58 | 0.76 | 1.54 | 15.4 | 38.9 | 76.9 | 154 |
| Input impendance Mohm | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 0.1 | 0.1 | |
| Voltage range/resolution | 0 to 24mA / 0.36µA | |||||||
| Accuracy | 0.1% of range | |||||||
| Signal input | Lower signals (max 1V) can be processed with the
standard cable YY-CP. Higher voltage levels require the
connection cable YY-CP. |
|||||||